Fork me on GitHub

The SEAS Electric Power System ontology

The SEAS Electric Power System Vocabulary defines:

  1. Electric power systems that consume, produce, or store electricity,
  2. electrical connections between electric power systems, where electricity is exchanged, and
  3. electrical connection Points of electric power systems, through which electricity flows in/out the power systems.

Classes

AlternatingCurrentConnection

Label: Alternating Current Connection

IRI: https://w3id.org/seas/AlternatingCurrentConnection

The class of electric power connections through which energy flows using alternating current.

AlternatingCurrentConnectionPoint

Label: Alternating Current Connection Point

IRI: https://w3id.org/seas/AlternatingCurrentConnectionPoint

The class of electric power connection points through which energy flows using alternating current.

AlternatingCurrentPowerProperty

Label: Alternating Current Power Property

IRI: https://w3id.org/seas/AlternatingCurrentPowerProperty

The class of electric power properties for alternating current.

An alternating current power property cannot be directly quantified. One must quantify its individual power properties.

AngleEvaluation

Label: Angle Evaluation

IRI: https://w3id.org/seas/AngleEvaluation

The class of evaluations for angle properties.

AngleProperty

Label: Angle Property

IRI: https://w3id.org/seas/AngleProperty

The class of properties that are quantifiable and measure the angle property .

ChargingEfficiencyEvaluation

Label: Charging Efficiency Evaluation

IRI: https://w3id.org/seas/ChargingEfficiencyEvaluation

The class of evaluations for efficiency properties.

ChargingEfficiencyProperty

Label: Charging Efficiency Property

IRI: https://w3id.org/seas/ChargingEfficiencyProperty

Charging Efficiency Property is a Efficiency Property which concern the charging process

CurrentEvaluation

Label: Current Evaluation

IRI: https://w3id.org/seas/CurrentEvaluation

The class of evaluations for current properties.

CurrentProperty

Label: Current Property

IRI: https://w3id.org/seas/CurrentProperty

The class of properties that are quantifiable and use a quantity dimension of electric current.

DigitalBallast

Label: Digital ballast

IRI: https://w3id.org/seas/DigitalBallast

A Digital ballast is a Ballast which is Digital

DirectCurrentConnection

Label: Direct Current Connection

IRI: https://w3id.org/seas/DirectCurrentConnection

The class of electrical connections through which energy flows using direct current.

EfficiencyEvaluation

Label: Efficiency Evaluation

IRI: https://w3id.org/seas/EfficiencyEvaluation

The class of evaluations for efficiency properties.

EfficiencyProperty

Label: Efficiency Property

IRI: https://w3id.org/seas/EfficiencyProperty

Efficiency signifies a level of performance that describes a process that uses the lowest amount of inputs to create the greatest amount of outputs. Efficiency relates to the use of all inputs in producing any given output, including personal time and energy. Efficiency is a measurable concept that can be determined by determining the ratio of useful output to total input. It minimizes the waste of resources such as physical materials, energy and time, while successfully achieving the desired output.

ElectricConductanceEvaluation

Label: Electric Conductance Evaluation

IRI: https://w3id.org/seas/ElectricConductanceEvaluation

The class of evaluations for electric conductance properties.

ElectricConductanceProperty

Label: Electric Conductance Property

IRI: https://w3id.org/seas/ElectricConductanceProperty

The class of properties that are quantifiable and have a quantity kind of electric conductance.

ElectricEnergyEvaluation

Label: Electric Energy Evaluation

IRI: https://w3id.org/seas/ElectricEnergyEvaluation

The class of evaluations for electric energy properties.

ElectricEnergyProperty

Label: Electric Energy Property

IRI: https://w3id.org/seas/ElectricEnergyProperty

The class of properties that are quantifiable and have a quantity kind of electric energy.

ElectricPowerConsumer

Label: Electric Power Consumer

IRI: https://w3id.org/seas/ElectricPowerConsumer

An electric power consumer is an electric power system that is capable of consuming electricity.

ElectricPowerDistributionNetwork

Label: Electric Power Distribution Network.

IRI: https://w3id.org/seas/ElectricPowerDistributionNetwork

Electric Power Distribution Network is a network used to distribute the electric power. Figure below shows the taxonomy of Electric Power Distribution Network according to the installation mode of Electric Line or cable. ElectricPowerDistributionNetworkTaxonomy

ElectricPowerEvaluation

Label: Electric Power Evaluation

IRI: https://w3id.org/seas/ElectricPowerEvaluation

The class of evaluations for electric power properties.

ElectricPowerLine

Label: Electric Power Line

IRI: https://w3id.org/seas/ElectricPowerLine

An electric power line is an electric transmission system that is capable of transmitting electricity on a certain distance within an electric power network.

An electric power line must be connected to two power connections, although this requirement cannot be modeled using OWL axioms if we want to remain in a decidable fragment.

ElectricPowerProducer

Label: Electric Power Producer

IRI: https://w3id.org/seas/ElectricPowerProducer

An electric power producer is an electric power system that is capable of producing electricity.

ElectricPowerProperty

Label: Electric Power Property

IRI: https://w3id.org/seas/ElectricPowerProperty

The class of properties that are quantifiable and have a quantity kind of electric power.

ElectricPowerStorageSystem

Label: Electric Power Storage System

IRI: https://w3id.org/seas/ElectricPowerStorageSystem

An electric power storage system is an electric power system that is capable of storing electricity. Usually a battery, an electric vehicle, or a microgrid

ElectricPowerSystem

Label: Electric Power System

IRI: https://w3id.org/seas/ElectricPowerSystem

The class of electric power systems, i.e., systems that exchange electricity (i.e., electric power) with other systems.

Electric power systems may consume, produce, or store electricity. Such systems are defined by subclasses of electric power system. Electric power systems that dissipate energy are thermodynamic systems (i.e., they can then dissipate heat).

Electric power systems can exchange electricity with other electric power systems. These exchange are only possible through electrical connections between electric power systems.

Electric power systems can have sub power systems:

ElectricPowerTransformer

Label: Electric Power Transformer

IRI: https://w3id.org/seas/ElectricPowerTransformer

An electric power transformer is an electric power system that is capable of transforming electricity within a power network, between a primary connection point and a secondary connection point.

ElectricPowerTransmissionSystem

Label: Electric Power Transmission System

IRI: https://w3id.org/seas/ElectricPowerTransmissionSystem

An electric power transmission system is an electric power system that is capable of transmitting electricity. Usually to transmit electricity on a certain distance within an electric power network, or to transform it.

ElectricReactanceEvaluation

Label: Electric Reactance Evaluation

IRI: https://w3id.org/seas/ElectricReactanceEvaluation

The class of evaluations for electric reactance properties.

ElectricReactanceProperty

Label: Electric Reactance Property

IRI: https://w3id.org/seas/ElectricReactanceProperty

The class of properties that are quantifiable and have a quantity kind of electric reactance.

ElectricResistanceEvaluation

Label: Electric Resistance Evaluation

IRI: https://w3id.org/seas/ElectricResistanceEvaluation

The class of evaluations for electric resistance properties.

ElectricResistanceProperty

Label: Electric Resistance Property

IRI: https://w3id.org/seas/ElectricResistanceProperty

The class of properties that are quantifiable and have a quantity kind of electric resistance.

ElectricSusceptanceEvaluation

Label: Electric Susceptance Evaluation

IRI: https://w3id.org/seas/ElectricSusceptanceEvaluation

The class of evaluations for electric susceptance properties.

ElectricSusceptanceProperty

Label: Electric Susceptance Property

IRI: https://w3id.org/seas/ElectricSusceptanceProperty

The class of properties that are quantifiable and have a quantity kind of electric susceptance.

ElectricalBallast

Label: Electrical Ballast

IRI: https://w3id.org/seas/ElectricalBallast

An electrical ballast is a device placed in line with the load to limit the amount of current in an electrical circuit. It may be a fixed or variable resistor. A familiar and widely used example is the inductive ballast used in fluorescent lamps to limit the current through the tube, which would otherwise rise to a destructive level due to the negative differential resistance artifact in the tube’s voltage-current characteristic. Ballasts vary greatly in complexity. They may be as simple as a resistor, inductor or capacitor (or a combination of these) wired in series with the lamp; or as complex as the electronic ballasts used in compact fluorescent lamps and high-intensity discharge lamps. (source:wikipedia)

ElectricalConnection

Label: Electrical Connection

IRI: https://w3id.org/seas/ElectricalConnection

The class of electrical connections between electric power systems. An electrical connection describes potential electricity flows between the electric power systems it connects. For example, the following RDF graph states that a power bus connects two power lines and a transformer:

  <power_bus> a seas:ElectricalConnection ;
    seas:connectsSystem <power_line_1> , <transformer> , <power_line_2> .

Only electric power systems and electrical connection points are connected through an electrical connection. A connection between electric power systems is not necessarily an electrical connection.

Any electric power system that exchanges electricity through an electrical connection is connected at least through one of its power connection points to the electrical connection: if:

  <power_system> a seas:ElectricPowerSystem .
  <power_connection> a seas:ElectricalConnection .
  <power_system> seas:connectedThrough <power_connection> .

then there exists _:powerConnectionPoint such that:

  _:powerConnectionPoint a seas:ElectricalConnectionPoint ;
    seas:connectionPointOf <power-system> ;
    seas:connectsSystemThrough <power_connection> .

ElectricalConnectionPoint

Label: Electrical Connection Point

IRI: https://w3id.org/seas/ElectricalConnectionPoint

The class of electrical connection points of electric power systems, at which they may be electricaly connected to other systems. For example, an electric vehicle service equipment may have three electric power connection points: two different kinds of plugs that enable to charge electric vehicles, and a three-phase power bus connection point to the grid:

  <electric_vehicle> a seas:ElectricPowerSystem ;
    seas:connectsAt <plug_high_voltage> , <normal_plug> , <three_phase_connection_point> .
  <plug_high_voltage> a seas:ElectricalConnectionPoint .
  <normal_plug> a seas:ElectricalConnectionPoint .
  <three_phase_connection_point> a seas:ElectricalConnectionPoint .

Any system connected through an electrical connection is connected at one of its electrical connection points to the electrical connection: if:

  <system> a seas:System .
  <system> seas:connectedThrough <connection> .
  <connection> a seas:ElectricalConnection .

then there exists _:connectionPoint such that:

  _:connectionPoint a seas:ElectricalConnection Point ;
    seas:connectionPointOf <system> ;
    seas:connectsSystemAt <connection> .

An electrical connection point describes an electric signal, and the electricity that enters/leaves the electric power system. An electrical connection point only belongs to an electric power system, and connects it through electrical connections. A connection point of an electric power system is not necessarily an electrical connection.

ElectronicBallast

Label: Electronic ballast

IRI: https://w3id.org/seas/ElectronicBallast

An electronic ballast uses solid state electronic circuitry to provide the proper starting and operating electrical conditions to power discharge lamps. An electronic ballast can be smaller and lighter than a comparably-rated magnetic one. An electronic ballast is usually quieter than a magnetic one, which produces a line-frequency hum by vibration of the transformer laminations. (source:wikipedia)

ExtraHighVoltage

Label: Extra-High Voltage

IRI: https://w3id.org/seas/ExtraHighVoltage

The voltage is Extra-High according to IEC 60038.

ExtraHighVoltageEvaluation

Label: Extra-High Voltage Evaluation

IRI: https://w3id.org/seas/ExtraHighVoltageEvaluation

The voltage is Extra-High according to IEC 60038.

ExtraLowVoltage

Label: Extra-Low Voltage

IRI: https://w3id.org/seas/ExtraLowVoltage

The voltage is Extra-Low according to IEC 60038.

ExtraLowVoltageEvaluation

Label: Extra-Low Voltage Evaluation

IRI: https://w3id.org/seas/ExtraLowVoltageEvaluation

The voltage is Extra-Low according to IEC 60038.

FacadeElectricPowerDistributionNetwork

Label: Facade Electric Power Distribution Network

IRI: https://w3id.org/seas/FacadeElectricPowerDistributionNetwork

A Facade Electric Power DistributionNetwork is an ElectricPowerDistributionNetwork which is hanging along a facade.

HighVoltage

Label: High Voltage

IRI: https://w3id.org/seas/HighVoltage

The voltage is High according to IEC 60038.

HighVoltageEvaluation

Label: High Voltage Evaluation

IRI: https://w3id.org/seas/HighVoltageEvaluation

The voltage is High according to IEC 60038.

LowVoltage

Label: Low Voltage

IRI: https://w3id.org/seas/LowVoltage

The voltage is Low according to IEC 60038.

LowVoltageEvaluation

Label: Low Voltage Evaluation

IRI: https://w3id.org/seas/LowVoltageEvaluation

The voltage is Low according to IEC 60038.

MagneticBallast

Label: Magnetic ballast

IRI: https://w3id.org/seas/MagneticBallast

A Magnetic ballast is a Ballast which is Magnetic

MediumVoltage

Label: Medium Voltage

IRI: https://w3id.org/seas/MediumVoltage

The voltage is Medium according to IEC 60038.

MediumVoltageEvaluation

Label: Medium Voltage Evaluation

IRI: https://w3id.org/seas/MediumVoltageEvaluation

The voltage is Medium according to IEC 60038.

OverheadElectricPowerDistributionNetwork

Label: Overhead Electric Power Distribution Network

IRI: https://w3id.org/seas/OverheadElectricPowerDistributionNetwork

An Overhead Electric Power DistributionNetwork is an ElectricPowerDistributionNetwork which is suspended in the air.

PowerBox

Label: Power box

IRI: https://w3id.org/seas/PowerBox

A power box (USA) or feeder pillar (UK) is a cabinet for electrical equipment, mounted in the street and controlling the electrical supply to a number of houses in a neighborhood. (source:wikipedia)

SinglePhaseConnectionPoint

Label: Single Phase Connection Point

IRI: https://w3id.org/seas/SinglePhaseConnectionPoint

A single phase connection point is a connection point composed of two wires (plus the protective earth):

SinglePhasePowerBus

Label: Single Phase Power Bus

IRI: https://w3id.org/seas/SinglePhasePowerBus

A single phase power bus is a connection composed of two wires (plus the protective earth): wire for the phase; wire for the neutral.

SplitPhaseConnectionPoint

Label: Split Phase Current Connection Point

IRI: https://w3id.org/seas/SplitPhaseConnectionPoint

The class of power connection points through which energy flows using split-phase alternating current.

SplitPhasePowerBus

Label: Split Phase Power Bus

IRI: https://w3id.org/seas/SplitPhasePowerBus

A split-phase power bus is a connection composed of three wires (plus the protective earth):

  • wire for the hot 1 phase;
  • wire for the neutral;
  • wire for the hot 2 phase.

ThreePhaseConnectionPoint

Label: Three-Phase Connection Point

IRI: https://w3id.org/seas/ThreePhaseConnectionPoint

A three-phase connection point is a connection point composed of four wires (plus the protective earth):

  • wires R, S, T, for the phases;
  • wire N for the neutral.

ThreeWireDirectCurrentConnectionPoint

Label: Three-Wire Direct Current Connection Point

IRI: https://w3id.org/seas/ThreeWireDirectCurrentConnectionPoint

A three-wire direct current power connection point is a connection point composed of three wires (potentialy plus the protective earth):

  • wire for the positive;
  • wire for the mid-wire;
  • wire for the negative.

ThreeWireDirectCurrentPowerBus

Label: Three-Wire Direct Current Power Bus

IRI: https://w3id.org/seas/ThreeWireDirectCurrentPowerBus

A three-wire direct current power bus is a connection composed of three wires (potentialy plus the protective earth): wire for the positive; wire for the mid-wire; wire for the negative.

TwoWireDirectCurrentConnectionPoint

Label: Two-Wire Direct Current Connection Point

IRI: https://w3id.org/seas/TwoWireDirectCurrentConnectionPoint

A two-wire direct current connection point is a connection point composed of two wires (potentialy plus the protective earth): wire for the positive; wire for the negative.

TwoWireDirectCurrentPowerBus

Label: Two-Wire Direct Current Power Bus

IRI: https://w3id.org/seas/TwoWireDirectCurrentPowerBus

A two-wire direct current power bus is a connection composed of two wires (potentialy plus the protective earth): wire for the positive; wire for the negative.

UndergroundElectricPowerDistributionNetwork

Label: Underground Electric Power Distribution Network

IRI: https://w3id.org/seas/UndergroundElectricPowerDistributionNetwork

An Underground Electric Power Distribution Network is an ElectricPowerDistributionNetwork which is buried underground.

VoltageEvaluation

Label: Voltage Evaluation

IRI: https://w3id.org/seas/VoltageEvaluation

The class of evaluations for voltage properties.

VoltageProperty

Label: Voltage Property

IRI: https://w3id.org/seas/VoltageProperty

The class of properties that are quantifiable and use a quantity dimension of electric potential.

Object Properties

RNConductance

Label: R-to-N conductance

IRI: https://w3id.org/seas/RNConductance

Links a three-phase connection point to the conductance between its R and its N wires.

RNReactance

Label: R-to-N reactance

IRI: https://w3id.org/seas/RNReactance

Links a three-phase connection point to the reactance between its R and its N wires.

RNResistance

Label: R-to-N resistance

IRI: https://w3id.org/seas/RNResistance

Links a three-phase connection point to the resistance between its R and its N wires.

RNSusceptance

Label: R-to-N susceptance

IRI: https://w3id.org/seas/RNSusceptance

Links a three-phase connection point to the susceptance between its R and its N wires.

RNVoltage

Label: R-to-N voltage

IRI: https://w3id.org/seas/RNVoltage

Links a three-phase power bus or a three-phase connection point to the voltage between its R and its N wires.

RSConductance

Label: R-to-S conductance

IRI: https://w3id.org/seas/RSConductance

Links a three-phase connection point to the conductance between its R and its S wires.

RSReactance

Label: R-to-S reactance

IRI: https://w3id.org/seas/RSReactance

Links a three-phase connection point to the reactance between its R and its S wires.

RSResistance

Label: R-to-S resistance

IRI: https://w3id.org/seas/RSResistance

Links a three-phase connection point to the resistance between its R and its S wires.

RSSusceptance

Label: R-to-S susceptance

IRI: https://w3id.org/seas/RSSusceptance

Links a three-phase connection point to the susceptance between its R and its S wires.

RSVoltage

Label: R-to-S voltage

IRI: https://w3id.org/seas/RSVoltage

Links a three-phase power bus or a three-phase connection point to the voltage between its R and its S wires.

SNConductance

Label: S-to-N conductance

IRI: https://w3id.org/seas/SNConductance

Links a three-phase connection point to the conductance between its S and its N wires.

SNReactance

Label: S-to-N reactance

IRI: https://w3id.org/seas/SNReactance

Links a three-phase connection point to the reactance between its S and its N wires.

SNResistance

Label: T-to-N resistance

IRI: https://w3id.org/seas/SNResistance

Links a three-phase connection point to the resistance between its S and its N wires.

SNSusceptance

Label: S-to-N susceptance

IRI: https://w3id.org/seas/SNSusceptance

Links a three-phase connection point to the susceptance between its S and its N wires.

SNVoltage

Label: S-to-N voltage

IRI: https://w3id.org/seas/SNVoltage

Links a three-phase power bus or a three-phase connection point to the voltage between its S and its N wires.

STConductance

Label: S-to-T conductance

IRI: https://w3id.org/seas/STConductance

Links a three-phase connection point to the conductance between its S and its T wires.

STReactance

Label: S-to-T reactance

IRI: https://w3id.org/seas/STReactance

Links a three-phase connection point to the reactance between its S and its T wires.

STResistance

Label: S-to-T resistance

IRI: https://w3id.org/seas/STResistance

Links a three-phase connection point to the resistance between its S and its T wires.

STSusceptance

Label: S-to-T susceptance

IRI: https://w3id.org/seas/STSusceptance

Links a three-phase connection point to the susceptance between its S and its T wires.

STVoltage

Label: S-to-T voltage

IRI: https://w3id.org/seas/STVoltage

Links a three-phase power bus or a three-phase connection point to the voltage between its S and its T wires.

TNConductance

Label: T-to-N conductance

IRI: https://w3id.org/seas/TNConductance

Links a three-phase connection point to the conductance between its T and its N wires.

TNReactance

Label: T-to-N reactance

IRI: https://w3id.org/seas/TNReactance

Links a three-phase connection point to the reactance between its T and its N wires.

TNResistance

Label: T-to-N resistance

IRI: https://w3id.org/seas/TNResistance

Links a three-phase connection point to the resistance between its T and its N wires.

TNSusceptance

Label: T-to-N susceptance

IRI: https://w3id.org/seas/TNSusceptance

Links a three-phase connection point to the susceptance between its T and its N wires.

TNVoltage

Label: T-to-N voltage

IRI: https://w3id.org/seas/TNVoltage

Links a three-phase power bus or a three-phase connection point to the voltage between its T and its N wires.

TRConductance

Label: T-to-R conductance

IRI: https://w3id.org/seas/TRConductance

Links a three-phase connection point to the conductance between its T and its R wires.

TRReactance

Label: T-to-R reactance

IRI: https://w3id.org/seas/TRReactance

Links a three-phase connection point to the reactance between its T and its R wires.

TRResistance

Label: T-to-R resistance

IRI: https://w3id.org/seas/TRResistance

Links a three-phase connection point to the resistance between its T and its R wires.

TRSusceptance

Label: T-to-R susceptance

IRI: https://w3id.org/seas/TRSusceptance

Links a three-phase connection point to the susceptance between its T and its R wires.

TRVoltage

Label: T-to-R voltage

IRI: https://w3id.org/seas/TRVoltage

Links a three-phase power bus or a three-phase connection point to the voltage between its T and its R wires.

activePower

Label: active power

IRI: https://w3id.org/seas/activePower

Links an alternating current power property to its active part (i.e., the real part of the complex value).

apparentPower

Label: active power

IRI: https://w3id.org/seas/apparentPower

Links an alternating current power property to its apparent part (i.e., the module of the complex value).

connectedInHot1Hot2Through

Label: connected in Hot1-to-Hot2 through

IRI: https://w3id.org/seas/connectedInHot1Hot2Through

Links an electric power system to a split-phase power bus connection with which it is connected with a hot1-to-hot2 configuration.

connectedInHot1NThrough

Label: connected in Hot1-to-N through

IRI: https://w3id.org/seas/connectedInHot1NThrough

Links an electric power system to a split-phase power bus connection with which it is connected with a hot1-to-N configuration.

connectedInHot2Hot1Through

Label: connected in Hot2-to-Hot1 through

IRI: https://w3id.org/seas/connectedInHot2Hot1Through

Links an electric power system to a split-phase power bus connection with which it is connected with a hot2-to-hot1 configuration.

connectedInHot2NThrough

Label: connected in Hot2-to-N through

IRI: https://w3id.org/seas/connectedInHot2NThrough

Links an electric power system to a split-phase power bus connection with which it is connected with a hot2-to-N configuration.

connectedInRNThrough

Label: connected in RN through

IRI: https://w3id.org/seas/connectedInRNThrough

Links an electric power system to a three-phase power bus connection with which it is connected with a RN configuration.

connectedInSNThrough

Label: connected in SN through

IRI: https://w3id.org/seas/connectedInSNThrough

Links an electric power system to a three-phase power bus connection with which it is connected with a SN configuration.

connectedInStarThrough

Label: connected in star through

IRI: https://w3id.org/seas/connectedInStarThrough

Links an electric power system to a three-phase power bus connection with which it is connected with a star configuration.

connectedInTNThrough

Label: connected in TN through

IRI: https://w3id.org/seas/connectedInTNThrough

Links an electric power system to a three-phase power bus connection with which it is connected with a TN configuration.

connectedInTriangleThrough

Label: connected in triangle through

IRI: https://w3id.org/seas/connectedInTriangleThrough

Links an electric power system to a three-phase power bus connection with which it is connected with a triangle configuration.

connectsPrimarilyAt

Label: connects primarily at

IRI: https://w3id.org/seas/connectsPrimarilyAt

Links an electric power transformer to its primary connection point

connectsSecondarilyAt

Label: connects secondarily at

IRI: https://w3id.org/seas/connectsSecondarilyAt

Links an electric power transformer to its secondary connection point

connectsSystemInHot1Hot2

Label: connects system in Hot1-to-Hot2

IRI: https://w3id.org/seas/connectsSystemInHot1Hot2

Links a split-phase power bus to one of the electric power systems it connects with a hot1-to-hot2 configuration.

connectsSystemInHot1N

Label: connects system in Hot1-to-N

IRI: https://w3id.org/seas/connectsSystemInHot1N

Links a split-phase power bus to one of the electric power systems it connects with a hot1-to-N configuration.

connectsSystemInHot2Hot1

Label: connects system in Hot2-to-Hot1

IRI: https://w3id.org/seas/connectsSystemInHot2Hot1

Links a split-phase power bus to one of the electric power systems it connects with a hot2-to-hot1 configuration.

connectsSystemInHot2N

Label: connects system in Hot2-to-N

IRI: https://w3id.org/seas/connectsSystemInHot2N

Links a split-phase power bus to one of the electric power systems it connects with a hot2-to-N configuration.

connectsSystemInRN

Label: connects system in RN

IRI: https://w3id.org/seas/connectsSystemInRN

Links a three-phase power bus to one of the electric power systems it connects with a RN configuration.

connectsSystemInRNAt

Label: connects system in RN at

IRI: https://w3id.org/seas/connectsSystemInRNAt

Links a three-phase power bus to one of the single phase connection points it connects with a RN configuration.

connectsSystemInRNThrough

Label: connects system in RN through

IRI: https://w3id.org/seas/connectsSystemInRNThrough

Links a single phase connection point to a three-phase power bus connection with which it is connected with a RN configuration.

connectsSystemInSN

Label: connects system in SN

IRI: https://w3id.org/seas/connectsSystemInSN

Links a three-phase power bus to one of the electric power systems it connects with a SN configuration.

connectsSystemInSNAt

Label: connects system in SN at

IRI: https://w3id.org/seas/connectsSystemInSNAt

Links a three-phase power bus to one of the single phase connection points it connects with a SN configuration.

connectsSystemInSNThrough

Label: connects system in SN through

IRI: https://w3id.org/seas/connectsSystemInSNThrough

Links a single phase connection point to a three-phase power bus connection with which it is connected with a SN configuration.

connectsSystemInStar

Label: connects system in star

IRI: https://w3id.org/seas/connectsSystemInStar

Links a three-phase power bus to one of the electric power systems it connects with a star configuration.

connectsSystemInStarAt

Label: connects system in star at

IRI: https://w3id.org/seas/connectsSystemInStarAt

Links a three-phase power bus to one of the three-phase connection points it connects with a star configuration.

connectsSystemInStarThrough

Label: connects system in star through

IRI: https://w3id.org/seas/connectsSystemInStarThrough

Links a three-phase connection point to a three-phase power bus connection with which it is connected with a star configuration.

connectsSystemInTN

Label: connects system in TN

IRI: https://w3id.org/seas/connectsSystemInTN

Links a three-phase power bus to one of the electric power systems it connects with a TN configuration.

connectsSystemInTNAt

Label: connects system in TN at

IRI: https://w3id.org/seas/connectsSystemInTNAt

Links a three-phase power bus to one of the single phase connection points it connects with a TN configuration.

connectsSystemInTNThrough

Label: connects system in TN through

IRI: https://w3id.org/seas/connectsSystemInTNThrough

Links a single phase connection point to a three-phase power bus connection with which it is connected with a TN configuration.

connectsSystemInTriangle

Label: connects system in triangle

IRI: https://w3id.org/seas/connectsSystemInTriangle

Links a three-phase power bus to one of the electric power systems it connects with a triangle configuration.

connectsSystemInTriangleAt

Label: connects system in triangle at

IRI: https://w3id.org/seas/connectsSystemInTriangleAt

Links a three-phase power bus to one of the three-phase connection points it connects with a triangle configuration.

connectsSystemInTriangleThrough

Label: connects system in triangle through

IRI: https://w3id.org/seas/connectsSystemInTriangleThrough

Links a three-phase connection point to a three-phase power bus connection with which it is connected with a triangle configuration.

consumedElectricEnergy

Label: consumed electric energy

IRI: https://w3id.org/seas/consumedElectricEnergy

Links an electric energy system to the consumed electric energy.

consumedElectricPower

Label: consumed electric power

IRI: https://w3id.org/seas/consumedElectricPower

Links an electric power system to the consumed electric power.

efficiency

Label: efficiency

IRI: https://w3id.org/seas/efficiency

The efficiency of the feature of interest.

electricConductance

Label: electric conductance

IRI: https://w3id.org/seas/electricConductance

Links an electrical connection point to one of its conductance properties.

There may be many conductance properties of an electrical connection point, so this property is not functional.

electricCurrent

Label: electrical current

IRI: https://w3id.org/seas/electricCurrent

Links an electrical connection point to one of its current properties.

There may be many current properties of a connection point, so this property is not functional.

electricEnergy

Label: electric energy

IRI: https://w3id.org/seas/electricEnergy

Links a feature of interest to one of its electric energy properties.

There may be many energy properties for a feature of interest, so this property is not functional.

electricEnergyBalance

Label: electric energy balance

IRI: https://w3id.org/seas/electricEnergyBalance

Links an electric energy system, or an electrical connection point, to the balance between the incoming electric energy and the outgoing electric energy.

electricPower

Label: electric power

IRI: https://w3id.org/seas/electricPower

Links a feature of interest to one of its electric power properties.

There may be many power properties for a feature of interest, so this property is not functional.

electricPowerBalance

Label: electric power balance

IRI: https://w3id.org/seas/electricPowerBalance

Links an electric power system, or an electrical connection point, to the balance between the incoming electric power and the outgoing electric power.

electricReactance

Label: electric reactance

IRI: https://w3id.org/seas/electricReactance

Links an electrical connection point to one of its reactance properties.

There may be many reactance properties of an electrical connection point, so this property is not functional.

electricResistance

Label: electric resistance

IRI: https://w3id.org/seas/electricResistance

Links an electrical connection point to one of its resistance properties.

There may be many resistance properties of an electrical connection point, so this property is not functional.

electricSusceptance

Label: electric susceptance

IRI: https://w3id.org/seas/electricSusceptance

Links an electrical connection point to one of its susceptance properties.

There may be many susceptance properties of an electrical connection point, so this property is not functional.

exchangesElectricityWith

Label: exchanges electricity with

IRI: https://w3id.org/seas/exchangesElectricityWith

Links an electric power system to another electric power system it exchanges electricity with.

This property can be qualified using class seas:ElectricalConnection, which connects (at least) the two electric power systems. For example, for the electricity to flow between a battery and a light, then they must share an electrical connection:

  <battery> a seas:ElectricPowerSystem .
  <light> a seas:ElectricPowerSystem .
  <battery> seas:exchangesElectricityWith <light> . 

If there is an electrical connection between several electric power systems, then one may infer these electric power systems can exchange electricity.

importedActiveEnergy

Label: imported active znergy

IRI: https://w3id.org/seas/importedActiveEnergy

Links an alternating current power property to its imported active energy, often in Wh/10.

incomingElectricEnergy

Label: incoming electric energy

IRI: https://w3id.org/seas/incomingElectricEnergy

Links an electric energy system, or an electrical connection point, to the incoming electric energy. (a) the sum of the electric energy that enter the system from the exterior, or (b) the electric energy that enters the system through this connection point.

incomingElectricPower

Label: incoming electric power

IRI: https://w3id.org/seas/incomingElectricPower

Links an electric power system, or an electrical connection point, to the incoming electric power. (a) the sum of the electric power that enter the system from the exterior, or (b) the electric power that enters the system through this connection point.

isPoweredBy

Label: is powered by

IRI: https://w3id.org/seas/isPoweredBy

links a System to it powered system.

length

Label: length

IRI: https://w3id.org/seas/length

The lenght of the feature of interest

midToNegativeConductance

Label: mid to negative conductance

IRI: https://w3id.org/seas/midToNegativeConductance

Links a direct current connection point to the conductance between its mid and its negative wires.

midToNegativeReactance

Label: mid to negative reactance

IRI: https://w3id.org/seas/midToNegativeReactance

Links a direct current connection point to the reactance between its mid and its negative wires.

midToNegativeResistance

Label: mid to negative resistance

IRI: https://w3id.org/seas/midToNegativeResistance

Links a direct current connection point to the resistance between its mid and its negative wires.

midToNegativeSusceptance

Label: mid to negative susceptance

IRI: https://w3id.org/seas/midToNegativeSusceptance

Links a direct current connection point to the susceptance between its mid and its negative wires.

midToNegativeVoltage

Label: mid to negative voltage

IRI: https://w3id.org/seas/midToNegativeVoltage

Links a direct current power bus or a direct current connection point to the voltage between its mid and its negative wires.

midWireCurrent

Label: mid wire current

IRI: https://w3id.org/seas/midWireCurrent

Links a direct current connection point to the current in its mid-wire. By convention, the value is positive if it enters the system.

Please contact us in case this convention is incorrect.

nCurrent

Label: N Current

IRI: https://w3id.org/seas/nCurrent

Links a three-phase connection point to the current in its N wire. By convention, the value is positive if it enters the system.

negativeWireCurrent

Label: negative wire current

IRI: https://w3id.org/seas/negativeWireCurrent

Links a direct current connection point to the current in its negative wire. By convention, the value is positive if it enters the system.

Please contact us in case this convention is incorrect.

neutralWireCurrent

Label: neutral wire current

IRI: https://w3id.org/seas/neutralWireCurrent

Links a single phase connection point to the current in its neutral wire. By convention, the value is positive if it leaves the system.

outgoingElectricEnergy

Label: outgoing electric energy

IRI: https://w3id.org/seas/outgoingElectricEnergy

Links an electric energy system, or an electrical connection point, to the outgoing electric energy. (a) the sum of the electric energy that leaves the system from the exterior, or (b) the electric energy that leaves the system through this connection point.

outgoingElectricPower

Label: outgoing electric power

IRI: https://w3id.org/seas/outgoingElectricPower

Links an electric power system, or an electrical connection point, to the outgoing electric power. (a) the sum of the electric power that leaves the system from the exterior, or (b) the electric power that leaves the system through this connection point.

phaseToNeutralConductance

Label: phase to neutral conductance

IRI: https://w3id.org/seas/phaseToNeutralConductance

Links a single phase connection point to the conductance between its phase and neutral wires.

phaseToNeutralReactance

Label: phase to neutral reactance

IRI: https://w3id.org/seas/phaseToNeutralReactance

Links a single phase connection point to the reactance between its phase and neutral wires.

phaseToNeutralResistance

Label: phase to neutral resistance

IRI: https://w3id.org/seas/phaseToNeutralResistance

Links a single phase connection point to the resistance between its phase and neutral wires.

phaseToNeutralSusceptance

Label: phase to neutral susceptance

IRI: https://w3id.org/seas/phaseToNeutralSusceptance

Links a single phase connection point to the susceptance between its phase and neutral wires.

phaseToNeutralVoltage

Label: phase to neutral voltage

IRI: https://w3id.org/seas/phaseToNeutralVoltage

Links a single phase power bus or a single phase connection point to the voltage between its phase and neutral wires.

phaseWireCurrent

Label: phase wire current

IRI: https://w3id.org/seas/phaseWireCurrent

Links a single phase connection point to the current in its phase wire. By convention, the value is positive if it enters the system.

positiveToMidConductance

Label: positive to mid conductance

IRI: https://w3id.org/seas/positiveToMidConductance

Links a direct current connection point to the conductance between its positive and its mid wires.

positiveToMidReactance

Label: positive to mid reactance

IRI: https://w3id.org/seas/positiveToMidReactance

Links a direct current connection point to the reactance between its positive and its mid wires.

positiveToMidResistance

Label: positive to mid resistance

IRI: https://w3id.org/seas/positiveToMidResistance

Links a direct current connection point to the resistance between its positive and its mid wires.

positiveToMidSusceptance

Label: positive to mid susceptance

IRI: https://w3id.org/seas/positiveToMidSusceptance

Links a direct current connection point to the susceptance between its positive and its mid wires.

positiveToMidVoltage

Label: positive to mid voltage

IRI: https://w3id.org/seas/positiveToMidVoltage

Links a direct current power bus or a direct current connection point to the voltage between its positive and its mid wires.

positiveToNegativeConductance

Label: positive to negative conductance

IRI: https://w3id.org/seas/positiveToNegativeConductance

Links a direct current connection point to the conductance between its positive and its negative wires.

positiveToNegativeReactance

Label: positive to negative reactance

IRI: https://w3id.org/seas/positiveToNegativeReactance

Links a direct current connection point to the reactance between its positive and its negative wires.

positiveToNegativeResistance

Label: positive to negative resistance

IRI: https://w3id.org/seas/positiveToNegativeResistance

Links a direct current connection point to the resistance between its positive and its negative wires.

positiveToNegativeSusceptance

Label: positive to negative susceptance

IRI: https://w3id.org/seas/positiveToNegativeSusceptance

Links a direct current connection point to the susceptance between its positive and its negative wires.

positiveToNegativeVoltage

Label: positive to negative voltage

IRI: https://w3id.org/seas/positiveToNegativeVoltage

Links a direct current power bus or a direct current connection point to the voltage between its positive and its negative wires.

positiveWireCurrent

Label: positive wire current

IRI: https://w3id.org/seas/positiveWireCurrent

Links a direct current connection point to the current in its positive wire. By convention, the value is positive if it enters the system.

Please contact us in case this convention is incorrect.

powerFactor

Label: power factor evaluation

IRI: https://w3id.org/seas/powerFactor

Links an alternating current power property to its power factor (i.e., the cosinus of the voltage with respect to current, unitless).

powers

Label: powers

IRI: https://w3id.org/seas/powers

links a system to the systems its powers.

primarilyConnectedThrough

Label: primarily connected through

IRI: https://w3id.org/seas/primarilyConnectedThrough

Links an electric power transformer to its primary connection

producedElectricEnergy

Label: produced electric energy

IRI: https://w3id.org/seas/producedElectricEnergy

Links an electric energy system to the produced electric energy.

producedElectricPower

Label: produced electric power

IRI: https://w3id.org/seas/producedElectricPower

Links an electric power system to the produced electric power.

rCurrent

Label: R Current

IRI: https://w3id.org/seas/rCurrent

Links a three-phase connection point to the current in its R wire. By convention, the value is positive if it enters the system.

reactivePower

Label: active power

IRI: https://w3id.org/seas/reactivePower

Links an alternating current power property to its reactive part (i.e., the imaginary part of the complex value).

sCurrent

Label: S Current

IRI: https://w3id.org/seas/sCurrent

Links a three-phase connection point to the current in its S wire. By convention, the value is positive if it enters the system.

secondarilyConnectedThrough

Label: secondarily connected through

IRI: https://w3id.org/seas/secondarilyConnectedThrough

Links an electric power transformer to its secondary connection

storageElectricPower

Label: storage electric power

IRI: https://w3id.org/seas/storageElectricPower

Links an electric power system to the storage electric power.

storedElectricEnergy

Label: stored electric energy

IRI: https://w3id.org/seas/storedElectricEnergy

Links an electric energy system to the stored electric energy.

subElectricPowerSystemOf

Label: sub electric power system of

IRI: https://w3id.org/seas/subElectricPowerSystemOf

Links an electric power system to its super electric power systems. The electricity of a sub power system contributes to the electricity of its super electric power system. For example,

  • The consumed electricity of an electric power comsumer system contributes to the consumed electricity of its super electric power consumer system;
  • The produced electricity of an electric power producer system contributes to the produced electricity of its super electric power producer system;
  • the stored electricity of an electric power storage system contributes to the stored electricity of its super electric power storage system.
  • sub property of: subSystemOf

  • domain: ElectricPowerSystem
  • range: ElectricPowerSystem

tCurrent

Label: T Current

IRI: https://w3id.org/seas/tCurrent

Links a three-phase connection point to the current in its T wire. By convention, the value is positive if it enters the system.

tapChanger

Label: tap Changer

IRI: https://w3id.org/seas/tapChanger

The Tap changer to change the voltage regulation of the transformer.

voltage

Label: voltage

IRI: https://w3id.org/seas/voltage

Links an electrical connection or an electrical connection point to one of its voltage properties.

There may be many voltage properties of an electrical connection or an electrical connection point, so this property is not functional.

voltageAngle

Label: voltage angle

IRI: https://w3id.org/seas/voltageAngle

Link the voltage property to the angle.