Contributors:
The SEAS Electric Power System Vocabulary defines:
Label: Alternating Current Connection
IRI: https://w3id.org/seas/AlternatingCurrentConnection
The class of electric power connections through which energy flows using alternating current.
sub class of: ElectricalConnection
Label: Alternating Current Connection Point
IRI: https://w3id.org/seas/AlternatingCurrentConnectionPoint
The class of electric power connection points through which energy flows using alternating current.
Label: Alternating Current Power Property
IRI: https://w3id.org/seas/AlternatingCurrentPowerProperty
The class of electric power properties for alternating current.
An alternating current power property cannot be directly quantified. One must quantify its individual power properties.
Label: Angle Evaluation
IRI: https://w3id.org/seas/AngleEvaluation
The class of evaluations for angle properties.
Label: Angle Property
IRI: https://w3id.org/seas/AngleProperty
The class of properties that are quantifiable and measure the angle property .
Label: Charging Efficiency Evaluation
IRI: https://w3id.org/seas/ChargingEfficiencyEvaluation
The class of evaluations for efficiency properties.
Label: Charging Efficiency Property
IRI: https://w3id.org/seas/ChargingEfficiencyProperty
Charging Efficiency Property is a Efficiency Property which concern the charging process
Label: Current Evaluation
IRI: https://w3id.org/seas/CurrentEvaluation
The class of evaluations for current properties.
Label: Current Property
IRI: https://w3id.org/seas/CurrentProperty
The class of properties that are quantifiable and use a quantity dimension of electric current.
Label: Digital ballast
IRI: https://w3id.org/seas/DigitalBallast
A Digital ballast is a Ballast which is Digital
Label: Direct Current Connection
IRI: https://w3id.org/seas/DirectCurrentConnection
The class of electrical connections through which energy flows using direct current.
Label: Direct Current Connection Point
IRI: https://w3id.org/seas/DirectCurrentConnectionPoint
The class of electrical connection points through which energy flows using direct current.
Label: Efficiency Evaluation
IRI: https://w3id.org/seas/EfficiencyEvaluation
The class of evaluations for efficiency properties.
Label: Efficiency Property
IRI: https://w3id.org/seas/EfficiencyProperty
Efficiency signifies a level of performance that describes a process that uses the lowest amount of inputs to create the greatest amount of outputs. Efficiency relates to the use of all inputs in producing any given output, including personal time and energy. Efficiency is a measurable concept that can be determined by determining the ratio of useful output to total input. It minimizes the waste of resources such as physical materials, energy and time, while successfully achieving the desired output.
Label: Electric Conductance Evaluation
IRI: https://w3id.org/seas/ElectricConductanceEvaluation
The class of evaluations for electric conductance properties.
Label: Electric Conductance Property
IRI: https://w3id.org/seas/ElectricConductanceProperty
The class of properties that are quantifiable and have a quantity kind of electric conductance.
Label: Electric Energy Evaluation
IRI: https://w3id.org/seas/ElectricEnergyEvaluation
The class of evaluations for electric energy properties.
Label: Electric Energy Property
IRI: https://w3id.org/seas/ElectricEnergyProperty
The class of properties that are quantifiable and have a quantity kind of electric energy.
Label: Electric Power Consumer
IRI: https://w3id.org/seas/ElectricPowerConsumer
An electric power consumer is an electric power system that is capable of consuming electricity.
Label: Electric Power Distribution Network.
IRI: https://w3id.org/seas/ElectricPowerDistributionNetwork
Electric Power Distribution Network is a network used to distribute the electric power. Figure below shows the taxonomy of Electric Power Distribution Network according to the installation mode of Electric Line or cable.
Label: Electric Power Evaluation
IRI: https://w3id.org/seas/ElectricPowerEvaluation
The class of evaluations for electric power properties.
Label: Electric Power Line
IRI: https://w3id.org/seas/ElectricPowerLine
An electric power line is an electric transmission system that is capable of transmitting electricity on a certain distance within an electric power network.
An electric power line must be connected to two power connections, although this requirement cannot be modeled using OWL axioms if we want to remain in a decidable fragment.
Label: Electric Power Producer
IRI: https://w3id.org/seas/ElectricPowerProducer
An electric power producer is an electric power system that is capable of producing electricity.
Label: Electric Power Property
IRI: https://w3id.org/seas/ElectricPowerProperty
The class of properties that are quantifiable and have a quantity kind of electric power.
Label: Electric Power Storage System
IRI: https://w3id.org/seas/ElectricPowerStorageSystem
An electric power storage system is an electric power system that is capable of storing electricity. Usually a battery, an electric vehicle, or a microgrid
Label: Electric Power System
IRI: https://w3id.org/seas/ElectricPowerSystem
The class of electric power systems, i.e., systems that exchange electricity (i.e., electric power) with other systems.
Electric power systems may consume, produce, or store electricity. Such systems are defined by subclasses of electric power system. Electric power systems that dissipate energy are thermodynamic systems (i.e., they can then dissipate heat).
Electric power systems can exchange electricity with other electric power systems. These exchange are only possible through electrical connections between electric power systems.
Electric power systems can have sub power systems:
sub class of: System
Label: Electric Power Transformer
IRI: https://w3id.org/seas/ElectricPowerTransformer
An electric power transformer is an electric power system that is capable of transforming electricity within a power network, between a primary connection point and a secondary connection point.
Label: Electric Power Transmission System
IRI: https://w3id.org/seas/ElectricPowerTransmissionSystem
An electric power transmission system is an electric power system that is capable of transmitting electricity. Usually to transmit electricity on a certain distance within an electric power network, or to transform it.
Label: Electric Reactance Evaluation
IRI: https://w3id.org/seas/ElectricReactanceEvaluation
The class of evaluations for electric reactance properties.
Label: Electric Reactance Property
IRI: https://w3id.org/seas/ElectricReactanceProperty
The class of properties that are quantifiable and have a quantity kind of electric reactance.
Label: Electric Resistance Evaluation
IRI: https://w3id.org/seas/ElectricResistanceEvaluation
The class of evaluations for electric resistance properties.
Label: Electric Resistance Property
IRI: https://w3id.org/seas/ElectricResistanceProperty
The class of properties that are quantifiable and have a quantity kind of electric resistance.
Label: Electric Susceptance Evaluation
IRI: https://w3id.org/seas/ElectricSusceptanceEvaluation
The class of evaluations for electric susceptance properties.
Label: Electric Susceptance Property
IRI: https://w3id.org/seas/ElectricSusceptanceProperty
The class of properties that are quantifiable and have a quantity kind of electric susceptance.
Label: Electrical Ballast
IRI: https://w3id.org/seas/ElectricalBallast
An electrical ballast is a device placed in line with the load to limit the amount of current in an electrical circuit. It may be a fixed or variable resistor. A familiar and widely used example is the inductive ballast used in fluorescent lamps to limit the current through the tube, which would otherwise rise to a destructive level due to the negative differential resistance artifact in the tube’s voltage-current characteristic. Ballasts vary greatly in complexity. They may be as simple as a resistor, inductor or capacitor (or a combination of these) wired in series with the lamp; or as complex as the electronic ballasts used in compact fluorescent lamps and high-intensity discharge lamps. (source:wikipedia)
Label: Electrical Connection
IRI: https://w3id.org/seas/ElectricalConnection
The class of electrical connections between electric power systems. An electrical connection describes potential electricity flows between the electric power systems it connects. For example, the following RDF graph states that a power bus connects two power lines and a transformer:
<power_bus> a seas:ElectricalConnection ; seas:connectsSystem <power_line_1> , <transformer> , <power_line_2> .
Only electric power systems and electrical connection points are connected through an electrical connection. A connection between electric power systems is not necessarily an electrical connection.
Any electric power system that exchanges electricity through an electrical connection is connected at least through one of its power connection points to the electrical connection: if:
<power_system> a seas:ElectricPowerSystem . <power_connection> a seas:ElectricalConnection . <power_system> seas:connectedThrough <power_connection> .
then there exists _:powerConnectionPoint such that:
_:powerConnectionPoint a seas:ElectricalConnectionPoint ; seas:connectionPointOf <power-system> ; seas:connectsSystemThrough <power_connection> .
Label: Electrical Connection Point
IRI: https://w3id.org/seas/ElectricalConnectionPoint
The class of electrical connection points of electric power systems, at which they may be electricaly connected to other systems. For example, an electric vehicle service equipment may have three electric power connection points: two different kinds of plugs that enable to charge electric vehicles, and a three-phase power bus connection point to the grid:
<electric_vehicle> a seas:ElectricPowerSystem ; seas:connectsAt <plug_high_voltage> , <normal_plug> , <three_phase_connection_point> . <plug_high_voltage> a seas:ElectricalConnectionPoint . <normal_plug> a seas:ElectricalConnectionPoint . <three_phase_connection_point> a seas:ElectricalConnectionPoint .
Any system connected through an electrical connection is connected at one of its electrical connection points to the electrical connection: if:
<system> a seas:System . <system> seas:connectedThrough <connection> . <connection> a seas:ElectricalConnection .
then there exists _:connectionPoint such that:
_:connectionPoint a seas:ElectricalConnection Point ; seas:connectionPointOf <system> ; seas:connectsSystemAt <connection> .
An electrical connection point describes an electric signal, and the electricity that enters/leaves the electric power system. An electrical connection point only belongs to an electric power system, and connects it through electrical connections. A connection point of an electric power system is not necessarily an electrical connection.
Label: Electronic ballast
IRI: https://w3id.org/seas/ElectronicBallast
An electronic ballast uses solid state electronic circuitry to provide the proper starting and operating electrical conditions to power discharge lamps. An electronic ballast can be smaller and lighter than a comparably-rated magnetic one. An electronic ballast is usually quieter than a magnetic one, which produces a line-frequency hum by vibration of the transformer laminations. (source:wikipedia)
Label: Extra-High Voltage
IRI: https://w3id.org/seas/ExtraHighVoltage
The voltage is Extra-High according to IEC 60038.
Label: Extra-High Voltage Evaluation
IRI: https://w3id.org/seas/ExtraHighVoltageEvaluation
The voltage is Extra-High according to IEC 60038.
Label: Extra-Low Voltage
IRI: https://w3id.org/seas/ExtraLowVoltage
The voltage is Extra-Low according to IEC 60038.
Label: Extra-Low Voltage Evaluation
IRI: https://w3id.org/seas/ExtraLowVoltageEvaluation
The voltage is Extra-Low according to IEC 60038.
Label: Facade Electric Power Distribution Network
IRI: https://w3id.org/seas/FacadeElectricPowerDistributionNetwork
A Facade Electric Power DistributionNetwork is an ElectricPowerDistributionNetwork which is hanging along a facade.
Label: High Voltage
IRI: https://w3id.org/seas/HighVoltage
The voltage is High according to IEC 60038.
Label: High Voltage Evaluation
IRI: https://w3id.org/seas/HighVoltageEvaluation
The voltage is High according to IEC 60038.
Label: Low Voltage
IRI: https://w3id.org/seas/LowVoltage
The voltage is Low according to IEC 60038.
Label: Low Voltage Evaluation
IRI: https://w3id.org/seas/LowVoltageEvaluation
The voltage is Low according to IEC 60038.
Label: Magnetic ballast
IRI: https://w3id.org/seas/MagneticBallast
A Magnetic ballast is a Ballast which is Magnetic
Label: Medium Voltage
IRI: https://w3id.org/seas/MediumVoltage
The voltage is Medium according to IEC 60038.
Label: Medium Voltage Evaluation
IRI: https://w3id.org/seas/MediumVoltageEvaluation
The voltage is Medium according to IEC 60038.
Label: Overhead Electric Power Distribution Network
IRI: https://w3id.org/seas/OverheadElectricPowerDistributionNetwork
An Overhead Electric Power DistributionNetwork is an ElectricPowerDistributionNetwork which is suspended in the air.
Label: Power box
IRI: https://w3id.org/seas/PowerBox
A power box (USA) or feeder pillar (UK) is a cabinet for electrical equipment, mounted in the street and controlling the electrical supply to a number of houses in a neighborhood. (source:wikipedia)
Label: Single Phase Connection Point
IRI: https://w3id.org/seas/SinglePhaseConnectionPoint
A single phase connection point is a connection point composed of two wires (plus the protective earth):
sub class of: AlternatingCurrentConnectionPoint
Label: Single Phase Power Bus
IRI: https://w3id.org/seas/SinglePhasePowerBus
A single phase power bus is a connection composed of two wires (plus the protective earth): wire for the phase; wire for the neutral.
Label: Split Phase Current Connection Point
IRI: https://w3id.org/seas/SplitPhaseConnectionPoint
The class of power connection points through which energy flows using split-phase alternating current.
Label: Split Phase Power Bus
IRI: https://w3id.org/seas/SplitPhasePowerBus
A split-phase power bus is a connection composed of three wires (plus the protective earth):
Label: Three-Phase Connection Point
IRI: https://w3id.org/seas/ThreePhaseConnectionPoint
A three-phase connection point is a connection point composed of four wires (plus the protective earth):
Label: Three-Phase Power Bus
IRI: https://w3id.org/seas/ThreePhasePowerBus
A three-phase power bus is a connection composed of four wires (plus the protective earth): wires R, S, T, for the phases; wire N for the neutral.
Label: Three-Wire Direct Current Connection Point
IRI: https://w3id.org/seas/ThreeWireDirectCurrentConnectionPoint
A three-wire direct current power connection point is a connection point composed of three wires (potentialy plus the protective earth):
Label: Three-Wire Direct Current Power Bus
IRI: https://w3id.org/seas/ThreeWireDirectCurrentPowerBus
A three-wire direct current power bus is a connection composed of three wires (potentialy plus the protective earth): wire for the positive; wire for the mid-wire; wire for the negative.
Label: Two-Wire Direct Current Connection Point
IRI: https://w3id.org/seas/TwoWireDirectCurrentConnectionPoint
A two-wire direct current connection point is a connection point composed of two wires (potentialy plus the protective earth): wire for the positive; wire for the negative.
Label: Two-Wire Direct Current Power Bus
IRI: https://w3id.org/seas/TwoWireDirectCurrentPowerBus
A two-wire direct current power bus is a connection composed of two wires (potentialy plus the protective earth): wire for the positive; wire for the negative.
Label: Underground Electric Power Distribution Network
IRI: https://w3id.org/seas/UndergroundElectricPowerDistributionNetwork
An Underground Electric Power Distribution Network is an ElectricPowerDistributionNetwork which is buried underground.
Label: Voltage Evaluation
IRI: https://w3id.org/seas/VoltageEvaluation
The class of evaluations for voltage properties.
Label: Voltage Property
IRI: https://w3id.org/seas/VoltageProperty
The class of properties that are quantifiable and use a quantity dimension of electric potential.
range of: RNVoltage, RSVoltage , SNVoltage , STVoltage , TNVoltage , TRVoltage , midToNegativeVoltage , phaseToNeutralVoltage , positiveToMidVoltage , positiveToNegativeVoltage , tapChanger , voltage
Label: R-to-N conductance
IRI: https://w3id.org/seas/RNConductance
Links a three-phase connection point to the conductance between its R and its N wires.
range: ElectricConductanceProperty
Label: R-to-N reactance
IRI: https://w3id.org/seas/RNReactance
Links a three-phase connection point to the reactance between its R and its N wires.
Label: R-to-N resistance
IRI: https://w3id.org/seas/RNResistance
Links a three-phase connection point to the resistance between its R and its N wires.
Label: R-to-N susceptance
IRI: https://w3id.org/seas/RNSusceptance
Links a three-phase connection point to the susceptance between its R and its N wires.
Label: R-to-N voltage
IRI: https://w3id.org/seas/RNVoltage
Links a three-phase power bus or a three-phase connection point to the voltage between its R and its N wires.
Label: R-to-S conductance
IRI: https://w3id.org/seas/RSConductance
Links a three-phase connection point to the conductance between its R and its S wires.
Label: R-to-S reactance
IRI: https://w3id.org/seas/RSReactance
Links a three-phase connection point to the reactance between its R and its S wires.
Label: R-to-S resistance
IRI: https://w3id.org/seas/RSResistance
Links a three-phase connection point to the resistance between its R and its S wires.
Label: R-to-S susceptance
IRI: https://w3id.org/seas/RSSusceptance
Links a three-phase connection point to the susceptance between its R and its S wires.
Label: R-to-S voltage
IRI: https://w3id.org/seas/RSVoltage
Links a three-phase power bus or a three-phase connection point to the voltage between its R and its S wires.
Label: S-to-N conductance
IRI: https://w3id.org/seas/SNConductance
Links a three-phase connection point to the conductance between its S and its N wires.
Label: S-to-N reactance
IRI: https://w3id.org/seas/SNReactance
Links a three-phase connection point to the reactance between its S and its N wires.
Label: T-to-N resistance
IRI: https://w3id.org/seas/SNResistance
Links a three-phase connection point to the resistance between its S and its N wires.
Label: S-to-N susceptance
IRI: https://w3id.org/seas/SNSusceptance
Links a three-phase connection point to the susceptance between its S and its N wires.
Label: S-to-N voltage
IRI: https://w3id.org/seas/SNVoltage
Links a three-phase power bus or a three-phase connection point to the voltage between its S and its N wires.
Label: S-to-T conductance
IRI: https://w3id.org/seas/STConductance
Links a three-phase connection point to the conductance between its S and its T wires.
Label: S-to-T reactance
IRI: https://w3id.org/seas/STReactance
Links a three-phase connection point to the reactance between its S and its T wires.
Label: S-to-T resistance
IRI: https://w3id.org/seas/STResistance
Links a three-phase connection point to the resistance between its S and its T wires.
Label: S-to-T susceptance
IRI: https://w3id.org/seas/STSusceptance
Links a three-phase connection point to the susceptance between its S and its T wires.
Label: S-to-T voltage
IRI: https://w3id.org/seas/STVoltage
Links a three-phase power bus or a three-phase connection point to the voltage between its S and its T wires.
Label: T-to-N conductance
IRI: https://w3id.org/seas/TNConductance
Links a three-phase connection point to the conductance between its T and its N wires.
Label: T-to-N reactance
IRI: https://w3id.org/seas/TNReactance
Links a three-phase connection point to the reactance between its T and its N wires.
Label: T-to-N resistance
IRI: https://w3id.org/seas/TNResistance
Links a three-phase connection point to the resistance between its T and its N wires.
Label: T-to-N susceptance
IRI: https://w3id.org/seas/TNSusceptance
Links a three-phase connection point to the susceptance between its T and its N wires.
Label: T-to-N voltage
IRI: https://w3id.org/seas/TNVoltage
Links a three-phase power bus or a three-phase connection point to the voltage between its T and its N wires.
Label: T-to-R conductance
IRI: https://w3id.org/seas/TRConductance
Links a three-phase connection point to the conductance between its T and its R wires.
Label: T-to-R reactance
IRI: https://w3id.org/seas/TRReactance
Links a three-phase connection point to the reactance between its T and its R wires.
Label: T-to-R resistance
IRI: https://w3id.org/seas/TRResistance
Links a three-phase connection point to the resistance between its T and its R wires.
Label: T-to-R susceptance
IRI: https://w3id.org/seas/TRSusceptance
Links a three-phase connection point to the susceptance between its T and its R wires.
Label: T-to-R voltage
IRI: https://w3id.org/seas/TRVoltage
Links a three-phase power bus or a three-phase connection point to the voltage between its T and its R wires.
Label: active power
IRI: https://w3id.org/seas/activePower
Links an alternating current power property to its active part (i.e., the real part of the complex value).
Label: active power
IRI: https://w3id.org/seas/apparentPower
Links an alternating current power property to its apparent part (i.e., the module of the complex value).
Label: connected in Hot1-to-Hot2 through
IRI: https://w3id.org/seas/connectedInHot1Hot2Through
Links an electric power system to a split-phase power bus connection with which it is connected with a hot1-to-hot2 configuration.
Label: connected in Hot1-to-N through
IRI: https://w3id.org/seas/connectedInHot1NThrough
Links an electric power system to a split-phase power bus connection with which it is connected with a hot1-to-N configuration.
Label: connected in Hot2-to-Hot1 through
IRI: https://w3id.org/seas/connectedInHot2Hot1Through
Links an electric power system to a split-phase power bus connection with which it is connected with a hot2-to-hot1 configuration.
Label: connected in Hot2-to-N through
IRI: https://w3id.org/seas/connectedInHot2NThrough
Links an electric power system to a split-phase power bus connection with which it is connected with a hot2-to-N configuration.
Label: connected in RN through
IRI: https://w3id.org/seas/connectedInRNThrough
Links an electric power system to a three-phase power bus connection with which it is connected with a RN configuration.
Label: connected in SN through
IRI: https://w3id.org/seas/connectedInSNThrough
Links an electric power system to a three-phase power bus connection with which it is connected with a SN configuration.
Label: connected in star through
IRI: https://w3id.org/seas/connectedInStarThrough
Links an electric power system to a three-phase power bus connection with which it is connected with a star configuration.
Label: connected in TN through
IRI: https://w3id.org/seas/connectedInTNThrough
Links an electric power system to a three-phase power bus connection with which it is connected with a TN configuration.
Label: connected in triangle through
IRI: https://w3id.org/seas/connectedInTriangleThrough
Links an electric power system to a three-phase power bus connection with which it is connected with a triangle configuration.
Label: connects primarily at
IRI: https://w3id.org/seas/connectsPrimarilyAt
Links an electric power transformer to its primary connection point
Label: connects secondarily at
IRI: https://w3id.org/seas/connectsSecondarilyAt
Links an electric power transformer to its secondary connection point
Label: connects system in Hot1-to-Hot2
IRI: https://w3id.org/seas/connectsSystemInHot1Hot2
Links a split-phase power bus to one of the electric power systems it connects with a hot1-to-hot2 configuration.
Label: connects system in Hot1-to-N
IRI: https://w3id.org/seas/connectsSystemInHot1N
Links a split-phase power bus to one of the electric power systems it connects with a hot1-to-N configuration.
Label: connects system in Hot2-to-Hot1
IRI: https://w3id.org/seas/connectsSystemInHot2Hot1
Links a split-phase power bus to one of the electric power systems it connects with a hot2-to-hot1 configuration.
Label: connects system in Hot2-to-N
IRI: https://w3id.org/seas/connectsSystemInHot2N
Links a split-phase power bus to one of the electric power systems it connects with a hot2-to-N configuration.
Label: connects system in RN
IRI: https://w3id.org/seas/connectsSystemInRN
Links a three-phase power bus to one of the electric power systems it connects with a RN configuration.
Label: connects system in RN at
IRI: https://w3id.org/seas/connectsSystemInRNAt
Links a three-phase power bus to one of the single phase connection points it connects with a RN configuration.
Label: connects system in RN through
IRI: https://w3id.org/seas/connectsSystemInRNThrough
Links a single phase connection point to a three-phase power bus connection with which it is connected with a RN configuration.
Label: connects system in SN
IRI: https://w3id.org/seas/connectsSystemInSN
Links a three-phase power bus to one of the electric power systems it connects with a SN configuration.
Label: connects system in SN at
IRI: https://w3id.org/seas/connectsSystemInSNAt
Links a three-phase power bus to one of the single phase connection points it connects with a SN configuration.
Label: connects system in SN through
IRI: https://w3id.org/seas/connectsSystemInSNThrough
Links a single phase connection point to a three-phase power bus connection with which it is connected with a SN configuration.
Label: connects system in star
IRI: https://w3id.org/seas/connectsSystemInStar
Links a three-phase power bus to one of the electric power systems it connects with a star configuration.
Label: connects system in star at
IRI: https://w3id.org/seas/connectsSystemInStarAt
Links a three-phase power bus to one of the three-phase connection points it connects with a star configuration.
Label: connects system in star through
IRI: https://w3id.org/seas/connectsSystemInStarThrough
Links a three-phase connection point to a three-phase power bus connection with which it is connected with a star configuration.
Label: connects system in TN
IRI: https://w3id.org/seas/connectsSystemInTN
Links a three-phase power bus to one of the electric power systems it connects with a TN configuration.
Label: connects system in TN at
IRI: https://w3id.org/seas/connectsSystemInTNAt
Links a three-phase power bus to one of the single phase connection points it connects with a TN configuration.
Label: connects system in TN through
IRI: https://w3id.org/seas/connectsSystemInTNThrough
Links a single phase connection point to a three-phase power bus connection with which it is connected with a TN configuration.
Label: connects system in triangle
IRI: https://w3id.org/seas/connectsSystemInTriangle
Links a three-phase power bus to one of the electric power systems it connects with a triangle configuration.
Label: connects system in triangle at
IRI: https://w3id.org/seas/connectsSystemInTriangleAt
Links a three-phase power bus to one of the three-phase connection points it connects with a triangle configuration.
Label: connects system in triangle through
IRI: https://w3id.org/seas/connectsSystemInTriangleThrough
Links a three-phase connection point to a three-phase power bus connection with which it is connected with a triangle configuration.
Label: consumed electric energy
IRI: https://w3id.org/seas/consumedElectricEnergy
Links an electric energy system to the consumed electric energy.
Label: consumed electric power
IRI: https://w3id.org/seas/consumedElectricPower
Links an electric power system to the consumed electric power.
Label: efficiency
IRI: https://w3id.org/seas/efficiency
The efficiency of the feature of interest.
Label: electric conductance
IRI: https://w3id.org/seas/electricConductance
Links an electrical connection point to one of its conductance properties.
There may be many conductance properties of an electrical connection point, so this property is not functional.
Label: electrical current
IRI: https://w3id.org/seas/electricCurrent
Links an electrical connection point to one of its current properties.
There may be many current properties of a connection point, so this property is not functional.
Label: electric energy
IRI: https://w3id.org/seas/electricEnergy
Links a feature of interest to one of its electric energy properties.
There may be many energy properties for a feature of interest, so this property is not functional.
Label: electric energy balance
IRI: https://w3id.org/seas/electricEnergyBalance
Links an electric energy system, or an electrical connection point, to the balance between the incoming electric energy and the outgoing electric energy.
Label: electric power
IRI: https://w3id.org/seas/electricPower
Links a feature of interest to one of its electric power properties.
There may be many power properties for a feature of interest, so this property is not functional.
Label: electric power balance
IRI: https://w3id.org/seas/electricPowerBalance
Links an electric power system, or an electrical connection point, to the balance between the incoming electric power and the outgoing electric power.
Label: electric reactance
IRI: https://w3id.org/seas/electricReactance
Links an electrical connection point to one of its reactance properties.
There may be many reactance properties of an electrical connection point, so this property is not functional.
Label: electric resistance
IRI: https://w3id.org/seas/electricResistance
Links an electrical connection point to one of its resistance properties.
There may be many resistance properties of an electrical connection point, so this property is not functional.
Label: electric susceptance
IRI: https://w3id.org/seas/electricSusceptance
Links an electrical connection point to one of its susceptance properties.
There may be many susceptance properties of an electrical connection point, so this property is not functional.
Label: exchanges electricity with
IRI: https://w3id.org/seas/exchangesElectricityWith
Links an electric power system to another electric power system it exchanges electricity with.
This property can be qualified using class seas:ElectricalConnection, which connects (at least) the two electric power systems. For example, for the electricity to flow between a battery and a light, then they must share an electrical connection:
<battery> a seas:ElectricPowerSystem . <light> a seas:ElectricPowerSystem . <battery> seas:exchangesElectricityWith <light> .
If there is an electrical connection between several electric power systems, then one may infer these electric power systems can exchange electricity.
Label: imported active znergy
IRI: https://w3id.org/seas/importedActiveEnergy
Links an alternating current power property to its imported active energy, often in Wh/10.
Label: incoming electric energy
IRI: https://w3id.org/seas/incomingElectricEnergy
Links an electric energy system, or an electrical connection point, to the incoming electric energy. (a) the sum of the electric energy that enter the system from the exterior, or (b) the electric energy that enters the system through this connection point.
Label: incoming electric power
IRI: https://w3id.org/seas/incomingElectricPower
Links an electric power system, or an electrical connection point, to the incoming electric power. (a) the sum of the electric power that enter the system from the exterior, or (b) the electric power that enters the system through this connection point.
Label: is powered by
IRI: https://w3id.org/seas/isPoweredBy
links a System to it powered system.
Label: length
IRI: https://w3id.org/seas/length
The lenght of the feature of interest
Label: mid to negative conductance
IRI: https://w3id.org/seas/midToNegativeConductance
Links a direct current connection point to the conductance between its mid and its negative wires.
Label: mid to negative reactance
IRI: https://w3id.org/seas/midToNegativeReactance
Links a direct current connection point to the reactance between its mid and its negative wires.
Label: mid to negative resistance
IRI: https://w3id.org/seas/midToNegativeResistance
Links a direct current connection point to the resistance between its mid and its negative wires.
Label: mid to negative susceptance
IRI: https://w3id.org/seas/midToNegativeSusceptance
Links a direct current connection point to the susceptance between its mid and its negative wires.
Label: mid to negative voltage
IRI: https://w3id.org/seas/midToNegativeVoltage
Links a direct current power bus or a direct current connection point to the voltage between its mid and its negative wires.
Label: mid wire current
IRI: https://w3id.org/seas/midWireCurrent
Links a direct current connection point to the current in its mid-wire. By convention, the value is positive if it enters the system.
Please contact us in case this convention is incorrect.
Label: N Current
IRI: https://w3id.org/seas/nCurrent
Links a three-phase connection point to the current in its N wire. By convention, the value is positive if it enters the system.
Label: negative wire current
IRI: https://w3id.org/seas/negativeWireCurrent
Links a direct current connection point to the current in its negative wire. By convention, the value is positive if it enters the system.
Please contact us in case this convention is incorrect.
Label: neutral wire current
IRI: https://w3id.org/seas/neutralWireCurrent
Links a single phase connection point to the current in its neutral wire. By convention, the value is positive if it leaves the system.
Label: outgoing electric energy
IRI: https://w3id.org/seas/outgoingElectricEnergy
Links an electric energy system, or an electrical connection point, to the outgoing electric energy. (a) the sum of the electric energy that leaves the system from the exterior, or (b) the electric energy that leaves the system through this connection point.
Label: outgoing electric power
IRI: https://w3id.org/seas/outgoingElectricPower
Links an electric power system, or an electrical connection point, to the outgoing electric power. (a) the sum of the electric power that leaves the system from the exterior, or (b) the electric power that leaves the system through this connection point.
Label: phase to neutral conductance
IRI: https://w3id.org/seas/phaseToNeutralConductance
Links a single phase connection point to the conductance between its phase and neutral wires.
Label: phase to neutral reactance
IRI: https://w3id.org/seas/phaseToNeutralReactance
Links a single phase connection point to the reactance between its phase and neutral wires.
Label: phase to neutral resistance
IRI: https://w3id.org/seas/phaseToNeutralResistance
Links a single phase connection point to the resistance between its phase and neutral wires.
Label: phase to neutral susceptance
IRI: https://w3id.org/seas/phaseToNeutralSusceptance
Links a single phase connection point to the susceptance between its phase and neutral wires.
Label: phase to neutral voltage
IRI: https://w3id.org/seas/phaseToNeutralVoltage
Links a single phase power bus or a single phase connection point to the voltage between its phase and neutral wires.
Label: phase wire current
IRI: https://w3id.org/seas/phaseWireCurrent
Links a single phase connection point to the current in its phase wire. By convention, the value is positive if it enters the system.
Label: positive to mid conductance
IRI: https://w3id.org/seas/positiveToMidConductance
Links a direct current connection point to the conductance between its positive and its mid wires.
Label: positive to mid reactance
IRI: https://w3id.org/seas/positiveToMidReactance
Links a direct current connection point to the reactance between its positive and its mid wires.
Label: positive to mid resistance
IRI: https://w3id.org/seas/positiveToMidResistance
Links a direct current connection point to the resistance between its positive and its mid wires.
Label: positive to mid susceptance
IRI: https://w3id.org/seas/positiveToMidSusceptance
Links a direct current connection point to the susceptance between its positive and its mid wires.
Label: positive to mid voltage
IRI: https://w3id.org/seas/positiveToMidVoltage
Links a direct current power bus or a direct current connection point to the voltage between its positive and its mid wires.
Label: positive to negative conductance
IRI: https://w3id.org/seas/positiveToNegativeConductance
Links a direct current connection point to the conductance between its positive and its negative wires.
Label: positive to negative reactance
IRI: https://w3id.org/seas/positiveToNegativeReactance
Links a direct current connection point to the reactance between its positive and its negative wires.
Label: positive to negative resistance
IRI: https://w3id.org/seas/positiveToNegativeResistance
Links a direct current connection point to the resistance between its positive and its negative wires.
Label: positive to negative susceptance
IRI: https://w3id.org/seas/positiveToNegativeSusceptance
Links a direct current connection point to the susceptance between its positive and its negative wires.
Label: positive to negative voltage
IRI: https://w3id.org/seas/positiveToNegativeVoltage
Links a direct current power bus or a direct current connection point to the voltage between its positive and its negative wires.
Label: positive wire current
IRI: https://w3id.org/seas/positiveWireCurrent
Links a direct current connection point to the current in its positive wire. By convention, the value is positive if it enters the system.
Please contact us in case this convention is incorrect.
Label: power factor evaluation
IRI: https://w3id.org/seas/powerFactor
Links an alternating current power property to its power factor (i.e., the cosinus of the voltage with respect to current, unitless).
Label: powers
IRI: https://w3id.org/seas/powers
links a system to the systems its powers.
Label: primarily connected through
IRI: https://w3id.org/seas/primarilyConnectedThrough
Links an electric power transformer to its primary connection
Label: produced electric energy
IRI: https://w3id.org/seas/producedElectricEnergy
Links an electric energy system to the produced electric energy.
Label: produced electric power
IRI: https://w3id.org/seas/producedElectricPower
Links an electric power system to the produced electric power.
Label: R Current
IRI: https://w3id.org/seas/rCurrent
Links a three-phase connection point to the current in its R wire. By convention, the value is positive if it enters the system.
Label: active power
IRI: https://w3id.org/seas/reactivePower
Links an alternating current power property to its reactive part (i.e., the imaginary part of the complex value).
Label: S Current
IRI: https://w3id.org/seas/sCurrent
Links a three-phase connection point to the current in its S wire. By convention, the value is positive if it enters the system.
Label: secondarily connected through
IRI: https://w3id.org/seas/secondarilyConnectedThrough
Links an electric power transformer to its secondary connection
Label: storage electric power
IRI: https://w3id.org/seas/storageElectricPower
Links an electric power system to the storage electric power.
Label: stored electric energy
IRI: https://w3id.org/seas/storedElectricEnergy
Links an electric energy system to the stored electric energy.
Label: sub electric power system of
IRI: https://w3id.org/seas/subElectricPowerSystemOf
Links an electric power system to its super electric power systems. The electricity of a sub power system contributes to the electricity of its super electric power system. For example,
sub property of: subSystemOf
Label: T Current
IRI: https://w3id.org/seas/tCurrent
Links a three-phase connection point to the current in its T wire. By convention, the value is positive if it enters the system.
Label: tap Changer
IRI: https://w3id.org/seas/tapChanger
The Tap changer to change the voltage regulation of the transformer.
Label: voltage
IRI: https://w3id.org/seas/voltage
Links an electrical connection or an electrical connection point to one of its voltage properties.
There may be many voltage properties of an electrical connection or an electrical connection point, so this property is not functional.
Label: voltage angle
IRI: https://w3id.org/seas/voltageAngle
Link the voltage property to the angle.